Show simple item record

dc.creatorNorouzi, Parvizen_US
dc.date.accessioned2004-10-21T00:11:35Zen_US
dc.date.accessioned2013-01-04T05:03:52Z
dc.date.available1998-11-01T08:00:00Zen_US
dc.date.available2013-01-04T05:03:52Z
dc.date.created1998-11en_US
dc.date.issued1998-11-01en_US
dc.date.submittedNovember 1998en_US
dc.identifier.urihttp://hdl.handle.net/10388/etd-10212004-001135en_US
dc.description.abstractIn this work, a new electrochemical detection method was developed with the ability to determine a wide range of inorganic and organic species at, trace levels. In brief, the detection method takes advantage of all possible electrochemical reactions that may occur during scanning of the electrode potential. Changes in the detector response are mainly the result of inhibition of oxygen adsorption and hydrogen adsorption, alteration of electrical properties of the double layer, or redox processes of the adsorbate. Various electrochemical techniques were examined in the measurements; i.e. cyclic voltammetry, pulse amperometric detection, and square wave voltammetry. In those electrochemical techniques, the detection was carried out in a stripping mode after accumulation of analytes on the electrode surface. The smallest discernable signal is associated with about 0.1% surface coverage, which corresponds to the adsorption of about 10-18 mol of analyte on a ultramicroelectrode 5-[mu]m in radius. The response time of the detector to the concentration change in most cases is less than 1s. Electrochemical conditioning of the working electrode is sufficient to ensure a stable response for a period of several hours. It appears that square wave and cyclic voltammetry techniques are more suitable for the detection method. The linear dynamic range of the calibration curve depends on the characteristic of the analyte-electrode bond and redox processes of the analyte, which may occur at the electrode surface. For instance, for strongly adsorbing molecules the linear dynamic range extends over two orders of magnitude from about 10 -7 M to 10-5 M and for electroactive compounds from about 10-8 M to 10-4 M. In general, the relative standard deviation for replicate determinations was lower than 5%. Moreover, in these analyses, removal of oxygen from the analyzed solutions is not required.en_US
dc.language.isoen_USen_US
dc.subjectchemistryen_US
dc.subjectchemical detectorsen_US
dc.subjectelectrochemical sensorsen_US
dc.subjectelectrochemistryen_US
dc.titleElectrochemical determination of surface active compounds at noble metal ultramicroelectrodes in flowing solutionsen_US
thesis.degree.departmentChemistryen_US
thesis.degree.disciplineChemistryen_US
thesis.degree.grantorUniversity of Saskatchewanen_US
thesis.degree.levelDoctoralen_US
thesis.degree.nameDoctor of Philosophy (Ph.D.)en_US
dc.type.materialtexten_US
dc.type.genreThesisen_US
dc.contributor.committeeMemberBaranski, Andrzej S.en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record