Repository logo
 

Predicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling

dc.contributor.advisorJohnston, James D.
dc.contributor.advisorKontulainen, Saija
dc.contributor.committeeMemberTrask, Catherine
dc.contributor.committeeMemberOdeshi, Akindele
dc.contributor.committeeMemberDolovich, Allan
dc.contributor.committeeMemberHawkes, Christopher
dc.creatorBunyamin, Amy
dc.date.accessioned2020-07-06T15:53:26Z
dc.date.available2020-07-06T15:53:26Z
dc.date.created2020-03
dc.date.issued2020-07-06
dc.date.submittedMarch 2020
dc.date.updated2020-07-06T15:53:27Z
dc.description.abstractDistal radius fractures are one of the most common types of fractures to occur in older adults. Bone strength (e.g., failure load) of the distal radius can be estimated using finite element (FE) models generated from high-resolution peripheral quantitative computed tomography (HR-pQCT) images; however, these models are limited because they determine failure load under pure compressive loading conditions and neglect off-axis loads that occur during a fall on an outstretched hand. The objective of this research was to identify moment arms in a HR-pQCT distal radius FE model that best predicted off-axis experimental failure load with highest explained variance and least error. We scanned the distal radius (9.5 mm site) of 21 fresh-frozen cadaveric forearms from female donors (82, SD 9 years) using HR-pQCT. We tested the specimens until fracture in a testing configuration set to simulate a fall on an outstretched hand to obtain experimental failure load. We created FE models which simulated off-axis loading. Specifically, we applied a point load at different medial-dorsal and lateral-dorsal moment arm combinations to determine predicted off-axis failure loads for different failure volumes and different failure criterion. We report the moment arm combination with the highest explained variance (R2) and lowest root mean squared error (RMSE%) in experimental failure loads. When incorporating off-axis loading, applying a 1 mm dorsal moment arm explained up to 79% of variance in experimental failure load, improving explained variance from pure compressive loading by 4%. These findings suggest that accounting for off-axis loading in current HR-pQCT FE models appear to offer modest improvement to the prediction of distal radius failure load which may potentially help to improve identification of individuals at risk of wrist fracture, and prevention and treatment therapies.
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/10388/12907
dc.subjectBone Strength
dc.subjectDistal Radius
dc.subjectFinite Element
dc.subjectHR-pQCT
dc.subjectOff-axis Loading
dc.subjectOsteoporosis
dc.titlePredicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling
dc.typeThesis
dc.type.materialtext
thesis.degree.departmentMechanical Engineering
thesis.degree.disciplineMechanical Engineering
thesis.degree.grantorUniversity of Saskatchewan
thesis.degree.levelMasters
thesis.degree.nameMaster of Science (M.Sc.)

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
BUNYAMIN-THESIS-2020.pdf
Size:
3.54 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
LICENSE.txt
Size:
2.27 KB
Format:
Plain Text
Description: