SCOUR IN STONE BEDS
dc.contributor.advisor | Smith, C. D. | |
dc.creator | Strang, Douglas Keith | |
dc.date.accessioned | 2020-02-06T21:16:46Z | |
dc.date.available | 2020-02-06T21:16:46Z | |
dc.date.issued | 1967-05 | |
dc.date.submitted | May 1967 | en_US |
dc.description.abstract | Energy dissipation in vertical drop structures is usually contained within concrete stilling basins. When suitable stone is available locally a satisfactory structure may be obtained at a lower cost by utilizing a stone bed to contain the zone of energy dissipation. Scour in stone beds downstream from vertical drop structures was investigated. Dimensionless charts are presented for the determination of scour hole dimensions. Criteria for dependable designs of stone beds are proposed. | en_US |
dc.identifier.uri | http://hdl.handle.net/10388/12582 | |
dc.title | SCOUR IN STONE BEDS | en_US |
dc.type.genre | Thesis | en_US |
thesis.degree.department | Civil Engineering | en_US |
thesis.degree.discipline | Civil Engineering | en_US |
thesis.degree.grantor | University of Saskatchewan | en_US |
thesis.degree.level | Masters | en_US |
thesis.degree.name | Master of Science (M.Sc.) | en_US |