Correlation between physical properties and flowability Indicators for fine powders
Date
2006-05-23
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
ORCID
Type
Degree Level
Masters
Abstract
Approximately 80% of pharmaceutical products and the ingredients required for their manufacture are in powder form. The solid dosage form (tablets and capsules) is manufactured by either dry-blending of fine powder ingredients or combining the ingredients in a wet granulation step, followed by drying. Arching, ratholing, caking, segregation and flooding are some of the commonly encountered flow problems in the handling of fine powders. These problems lead to losses worth thousands of dollars at production scale. Poor powder flowability is a consequence of the combined effects of many variables, including improper equipment design, particle size, size distribution, shape, moisture content and surface texture. In the present work, a systematic study has been performed to determine the relationship between the flowability of fine powders and their physical properties of mean size and size distribution, density and shape. Flowability studies were done on six different powders: the NutraSweet® Brand sweetener (aspartame), Respitose ML001, Alpha-D-Lactose monohydrate, the pharmaceutical binder Methocel (R) F50 Premium Hydroxypropyl methylcellulose- HPMC, a placebo pharmaceutical granulate, and common pastry flour. Scanning electron microscopy (SEM) and stereomicroscopy were used for particle shape and size analysis. Particle size distribution was determined using the laser light scattering technique. Powder flowability was measured using shear strength, angle of repose, and tapped-to-bulk density measurements. A novel method of measuring the dynamic angle of repose using electrical capacitance tomography (ECT) was developed. Analysis of the images from microscopy revealed that the particles of aspartame and HPMC powders were elongated, the particles of ML001, pastry flour and lactose monohydrate powders were irregular, and the particles of placebo granulate were nearly spherical. Particle size was found to be the most reliable indicator of powder flowability, with decreasing particle size corresponding to lower flowability; however other parameters such as particle elongation and irregularity, were also found to have an influence on powder flowability. Although HPMC and pastry flour had similar particle sizes, they exhibited differences in flowability. This can be explained by the greater irregularity of the flour particles. Particle irregularity may cause mechanical interlocking between the particles, thus reducing powder flowability. ECT was found to be a promising non-intrusive tool for the measurement of the dynamic angle of repose. Unlike other methods for the measurement of dynamic angle of repose, the results obtained from ECT were not influenced by the effect of end caps. The present technique could be used by pharmaceutical industries in process analytical technology (PAT) for the detection and elimination of potential flow problems early in the manufacturing process.
Description
Keywords
particle shape, particle size, fine powders, Powder flowability, shear strength
Citation
Degree
Master of Science (M.Sc.)
Department
Chemical Engineering
Program
Chemical Engineering