Abstract

The design of a voltage integrator having six input ranges ranging from 1 milli-volt full scale to 100 volt full scale, together with a digital read out is described. This equipment is capable of recording the time integral of the input voltage for a period of about three months. Under nor-mal working conditions it has a stability off 0.1 percent referred to full scale. From 0 to 70 percent of full scale it has a linearity of ± 0.5 percent. The error then increases from 0 percent-at 75 percent of full scale to a maximum of 2 percent at full scale.