Sort Options
Item A transient numerical model for desiccant-coated fixed-bed regenerators and compensation for transient sensor errors(Taylor and Francis, 2021-12) Ramin, Hadi; Krishnan, Easwaran K; Gurubalan, A; Simonson, Carey JDesiccant-coated fixed-bed regenerators (FBRs) can achieve high effectiveness due to high ratio of energy transfer area to volume, and therefore, they are favourable air-to-air energy recovery exchangers for HVAC systems. However, unlike other types of energy recovery exchangers, the air properties (i.e., temperature and humidity) at the outlet of FBRs vary with time. The variations in outlet airflow properties can cause errors in measurements because the measurements include the FBR and sensors transient responses. In this paper, a numerical model is developed to evaluate the performance of desiccant-coated FBRs and their transient operation. The model consists of an exchanger model (FBR model) and sensor (temperature and humidity) models to distinguish the actual performance of the FBR alone from the measured performance, which includes both the FBR and the sensor's response. The model is validated with experimental measurements and available results in the literature. The model can decouple the measured response of the FBR and sensors to predict the FBR performance. This paper's main contribution is an insight into the complex heat and mass transfer processes in desiccant-coated FBRs and measurement sensors. The results of this paper could be used to provide practical recommendations for humidity measurements of different types of desiccant-coated FBRs developed for HVAC applications. Furthermore, the measurement requirements in the current testing standards (ASHRAE 84 and CSA C439-18 standards) for FBRs are examined. Recommendations from this paper could be implemented in future versions of these standards.Item Transient sensor errors and their impact on fixed-bed regenerator (FBR) testing standards(Taylor and Francis, 2020-12) Ramin, Hadi; Krishnan, Easwaran K; Gurubalan, Annadurai; Alabi, Wahab O; Simonson, Carey JFixed-bed regenerators (FBRs) are a favorable option for energy recovery in building HVAC systems due to their high sensible effectiveness. Unlike other types of energy recovery exchangers, the air temperature at the outlet of FBRs varies with time, which creates challenges when measuring the outlet temperature and effectiveness of FBRs since the actual outlet air temperature will include the transient response of the FBR and the temperature sensor. In this article, a validated numerical model of FBRs that takes into account the sensor response is used to quantify the temperature and effectiveness errors that result due to sensors’ response characteristics over a wide range of design parameters. The main contributions of this article are the practical recommendations for the temperature measurement for different types of FBRs developed for HVAC applications. The recommendations presented in this article could be implemented in future versions of the current standards (ASHRAE 84 and CSA C439-18 standards) for performance testing of air-to-air energy exchangers.