Effects of Variations in Incident Heat Flux When Using Cone Calorimeter Test Data for Prediction of Full-Scale Heat Release Rates of Polyurethane Foam

dc.contributor.authorRobson, Luke
dc.contributor.authorTorvi, David
dc.contributor.authorObach, Matthew
dc.contributor.authorWeckman, Elizabeth
dc.date.accessioned2021-07-19T17:45:40Z
dc.date.available2021-07-19T17:45:40Z
dc.date.issued2016
dc.descriptionThis is the peer reviewed version of the following article: Robson LD, Torvi DA, Obach MR and Weckman EJ (2016). Effects of Variations in Incident Heat Flux When Using Cone Calorimeter Test Data for Prediction of Full-Scale Heat Release Rates of Polyurethane Foam. Fire and Materials, 40:89-113 which has been published in final form at https://doi.org/10.1002/fam.2271. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Us of Self-Archived Versions.en_US
dc.description.abstractThe development of methods to predict full-scale fire behaviour using small-scale test data is of great interest to the fire community. This study evaluated the ability of one model, originally developed during the European Combustion Behaviour of Upholstered Furniture (CBUF) project, to predict heat release rates. Polyurethane foam specimens were tested in the furniture calorimeter using both centre and edge ignition locations. Input data was obtained using cone calorimeter tests and infrared video-based flame area measurements. Two particular issues were investigated: how variations in incident heat flux in cone calorimeter tests impact heat release rate predictions, and the ability of the model to predict results for different foam thicknesses. Heat release rate predictions showed good agreement with experimental results, particularly during the growth phase of the fire. The model was more successful in predicting results for edge ignition tests than for centre ignition tests, and in predicting results for thinner foams. Results indicated that, due to sensitivity of the burning behaviour to foam specimen geometry and ignition location, a single incident heat flux could not be specified for generating input for the CBUF model. Potential methods to determine appropriate cone calorimeter input for various geometries and ignition locations are discussed.en_US
dc.description.sponsorshipNSERC (RGPIN: 238260-10)en_US
dc.description.versionPeer Revieweden_US
dc.identifier.citationRobson, L.D., Torvi, D.A., Obach, M.R. & Weckman, E.J. (2016). Effects of Variations in Incident Heat Flux When Using Cone Calorimeter Test Data for Prediction of Full-Scale Heat Release Rates of Polyurethane Foam. Fire and Materials, 40: 89-113. https://doi.org/10.1002/fam.2271en_US
dc.identifier.urihttps://hdl.handle.net/10388/13484
dc.language.isoenen_US
dc.publisherWileyen_US
dc.subjectfurniture calorimeteren_US
dc.subjectfire testingen_US
dc.subjectcone calorimeteren_US
dc.subjectfire modelingen_US
dc.subjectscalingen_US
dc.subjectpolyurethane foamen_US
dc.titleEffects of Variations in Incident Heat Flux When Using Cone Calorimeter Test Data for Prediction of Full-Scale Heat Release Rates of Polyurethane Foamen_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Robson_et_al_Fire_Mtls_2016_sub.pdf
Size:
1.52 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.28 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections