Repository logo
 

Evaluation of transfixation cast constructs in horses

dc.contributor.advisorCarmalt, James L
dc.contributor.committeeMemberWilson, David G
dc.contributor.committeeMemberJohnston, James D
dc.contributor.committeeMemberHarding, John
dc.contributor.committeeMemberGilbert, Peter
dc.creatorThomas, Keri Lee Lang 1979-
dc.creator.orcid0000-0001-9853-5561
dc.date.accessioned2018-07-27T20:48:54Z
dc.date.available2018-07-27T20:48:54Z
dc.date.created2018-06
dc.date.issued2018-07-27
dc.date.submittedJune 2018
dc.date.updated2018-07-27T20:48:54Z
dc.description.abstractTransfixation pin casts have been used to manage a variety of different equine fracture configurations, but are particularly useful in comminuted fractures of the distal limb. The objectives of this study were to investigate strain at the bone-pin interface, the cast, and the fracture site, as well as load transfer between the bone and cast in different equine transfixation pin cast configurations. Three transfixation pin cast configurations (5 forelimbs per group) were evaluated: Construct 1: Two, 6.3-mm diameter pins spaced 4-cm apart in the cannon bone; Construct 2: Two, 6.3-mm diameter pins spaced 5-cm apart; Construct 3: Four, 4.8-mm diameter pins spaced 2-cm apart. Strain gauges were attached to the cast, cannon bone, and adjacent to a simulated fracture in the proximal phalanx. Limbs were subjected to single cycle compressive loading to failure as well as cyclic loading that simulated 6 weeks of wearing a cast. A simplified finite element (FE) model of Construct 1 and 3 was used to further evaluate strain and load transfer between the bone and cast during load to failure and cyclic loading. The results indicated that there was no difference in strain between the two 2-pin constructs in load to failure or cyclic loading. Relative to the 2-pin constructs, the 4-pin construct had less strain at the bone-pin interface and more strain in the cast, indicating that more load is transferred to the cast with the 4-pin construct. In-line with these findings, FE analyses indicated that the 4-pin system had less bone strain at the bone-pin interface, less strain adjacent to the fracture site, and less load transferred to the bone. These results suggest that the 4-pin cast is more effective at unloading the fractured bone.
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/10388/9219
dc.subjectTransfixation pin casts
dc.subjectexternal skeletal fixators
dc.subjectfractures
dc.subjectequine
dc.subjecthorses
dc.titleEvaluation of transfixation cast constructs in horses
dc.typeThesis
dc.type.materialtext
thesis.degree.departmentLarge Animal Clinical Sciences
thesis.degree.disciplineLarge Animal Clinical Sciences
thesis.degree.grantorUniversity of Saskatchewan
thesis.degree.levelMasters
thesis.degree.nameMaster of Science (M.Sc.)

Files

Original bundle
Now showing 1 - 5 of 5
Loading...
Thumbnail Image
Name:
THOMAS-THESIS-2018.pdf
Size:
10.38 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Keri Thomas MSc Thesis 2018_4.docx
Size:
20.43 MB
Format:
Microsoft Word XML
No Thumbnail Available
Name:
Keri Thomas MSc Thesis 2018_3.docx
Size:
20.43 MB
Format:
Microsoft Word XML
No Thumbnail Available
Name:
Keri Thomas MSc Thesis 2018_2.docx
Size:
20.43 MB
Format:
Microsoft Word XML
No Thumbnail Available
Name:
Keri Thomas MSc Thesis 2018_1.docx
Size:
20.43 MB
Format:
Microsoft Word XML
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
LICENSE.txt
Size:
2.27 KB
Format:
Plain Text
Description: