A STUDY OF THE STANDSTILL FREQUENCY RESPONSE TEST FOR SYNCHRONOUS MACHINES

dc.contributor.advisorEl-Serafi, A. M.
dc.creatorJin, Yusun
dc.date.accessioned2018-12-14T20:23:48Z
dc.date.available2018-12-14T20:23:48Z
dc.date.issued1988-06
dc.date.submittedJune 1988en_US
dc.description.abstractin recent years, the Standstill Frequency Response (SSFR) test has been accepted as a powerful tool for the determination of synchronous machine parameters. However, the existing techniques of the SSFR test still have a number of shortcomings which affect the accuracy of the test. This thesis is devoted to examine some of these shortcomings and to develop ways to enhance the accuracy of this test. Both simulations and experiments have been employed in carrying out this research. This thesis has investigated the concept of the SSFR test and proposed to involve three d-axis transfer functions in it instead of the commonly used two functions. This involvement can improve the accuracy of the SSFR test. Since the accuracy of the determined machine parameters depends greatly on the accuracy of the transfer function measurement, this thesis has also investigated intensively the various sources of errors in conducting the SSFR test, and the means to eliminate or reduce such errors. Since the accuracy of the determined parameters depends also on the model fitting process, an effective nonlinear model fitting technique, namely the Marquardt algorithm, has been adapted successfully for the synchronous machine parameter estimation. To verify the developed techniques, an SSFR test has been carried out on a microalternator to determine its parameters. A VAX 11/780 computer and an LP All-K system have been utilized to implement the A/D conversion for the signals with a wide range of frequencies, and to perform the data processing. The conducted SSFR test has been designed to suit the conditions of various magnetic flux levels in synchronous machines. This thesis describes in detail the developed techniques and the conducted SSFR testing. Test results are also presented and discussed.en_US
dc.identifier.urihttp://hdl.handle.net/10388/11653
dc.titleA STUDY OF THE STANDSTILL FREQUENCY RESPONSE TEST FOR SYNCHRONOUS MACHINESen_US
dc.type.genreThesisen_US
thesis.degree.departmentElectrical and Computer Engineeringen_US
thesis.degree.disciplineElectrical Engineeringen_US
thesis.degree.grantorUniversity of Saskatchewanen_US
thesis.degree.levelMastersen_US
thesis.degree.nameMaster of Science (M.Sc.)en_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Jin_Yusun_1988_sec.pdf
Size:
13.2 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.07 KB
Format:
Item-specific license agreed upon to submission
Description: