Front end x-ray beam position monitors at the Canadian Light Source

dc.contributor.advisorJiang, De-Tongen_US
dc.contributor.advisorBergstrom, Jack C.en_US
dc.contributor.committeeMemberMoewes, Alexanderen_US
dc.contributor.committeeMemberManson, Alanen_US
dc.contributor.committeeMemberGrochulski, Pawelen_US
dc.contributor.committeeMemberChapman, L. Deanen_US
dc.contributor.committeeMemberXiao, Chijinen_US
dc.creatorSmith, Sheldon Jamesen_US
dc.date.accessioned2006-10-03T13:54:32Zen_US
dc.date.accessioned2013-01-04T05:00:34Z
dc.date.available2006-10-04T08:00:00Zen_US
dc.date.available2013-01-04T05:00:34Z
dc.date.created2006-09en_US
dc.date.issued2006-09-15en_US
dc.date.submittedSeptember 2006en_US
dc.description.abstractThe development of X-ray Beam Position Monitors (XBPM) used on the Canadian Light Source front ends is described in this thesis, from the design concepts to the practical implementation and commissioning. Surveyed into position to provide a fiducialized point of origin for incoming synchrotron radiation, the primary purpose of the XBPM is to provide a measure of synchrotron beam motion. Currently XBPMs have been installed on three beamlines at the Canadian Light Source, a 2.9 GeV third generation synchrotron radiation source. Two of the XBPMs are comprised of chemical vapour deposition synthetic diamond blades coated with gold and installed on insertion device beamlines, while the third makes use of molybdenum blades for a dipole beamline. By incrementally scanning the blades of the XBPM through the synchrotron beam it is possible to determine the monitors' spatial resolution to beam motion. For the commissioned XBPM a typical spatial resolution of +/- 1 micron of beam motion was achieved; and the thermal power loading capacity has been tested to the 2/5 of maximum value. An independent white beam profiler, comprised of a converter crystal and image acquisition software, was constructed to corroborate the functionality of the XBPM.en_US
dc.identifier.urihttp://hdl.handle.net/10388/etd-10032006-135432en_US
dc.language.isoen_USen_US
dc.subjectx-ray beam position monitoren_US
dc.subjectsynchrotron radiationen_US
dc.subjectfront enden_US
dc.titleFront end x-ray beam position monitors at the Canadian Light Sourceen_US
dc.type.genreThesisen_US
dc.type.materialtexten_US
thesis.degree.departmentPhysics and Engineering Physicsen_US
thesis.degree.disciplinePhysics and Engineering Physicsen_US
thesis.degree.grantorUniversity of Saskatchewanen_US
thesis.degree.levelMastersen_US
thesis.degree.nameMaster of Science (M.Sc.)en_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
SheldonSmithThesis.pdf
Size:
8.37 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
905 B
Format:
Plain Text
Description: